SMART ODME – Oil Discharge Monitoring Equipment

The Oil Discharge Monitoring Equipment (SMART ODME) is a slop water monitor for tankers.

The SMART ODME has been designed to provide means of monitoring, recording and controlling the ballast discharge for crude oil, product and chemical tankers including ICE class vessels.

This system is modular in construction and does not require the usual pump/motor bulkhead penetration as used on older systems.

The SMART ODME includes all components required to meet MEPC 108(49) and the latest MEPC 240(65) for bio fuels, effective 1 January 2016.

The SMART ODME incorporates a ‘simulation mode’ to aid system demonstration to PSC surveyors and is designed for ease of retrofitting, operation, installation and maintenance. Discharge limits are set at 30 litres of oil per nautical mile or 1/30

Overview

The Oil Discharge Monitoring Equipment (Smart ODME) has been designed to provide means of monitoring, recording and controlling the ballast discharge for crude oil, product and chemical tankers including ICE class vessels.
This system is modular in construction and does not require the usual pump/motor bulkhead penetration as used on older systems. The Smart ODME includes all components required to meet MEPC 108(49) and the latest MEPC 240(65) for Bio Fuels, effective 1 January 2016.

The Smart ODME incorporates a ‘simulation mode’ to aid system demonstration to PSC surveyors, is designed for ease of retrofitting, operation, installation and maintenance.

Discharge limits are set at 30 litres of Oil per nautical mile or 1 / 30,000 of the previous cargo for slop and wash water discharges.

Applications

  • Slop Water Discharge
  • Tank Wash Water Discharge
  • Clean Ballast Water Discharge

Technical Specifications

MEASUREMENT
Oil types As Per MEPC 108(49) + MEPC 240(65) requirements
Clean water calibration Automatic
Oil measurement range 0 – 1000 ppm all types
Resolution 1 ppm
Accuracy oil + solids As Per MEPC 108(49) requirements
DATA STORAGE AND RETRIEVAL
Data retrieval via LCD display or download to PC using HyperTerminal or Rivertrace IMO Log downloader programme
ENVIRONMENTAL & SAMPLE
Sample Pressure Range 0.1bar to 5bar
Sample Flow Rate 4Lpm to 5Lpm
Sample Temperature 1⁰C to 40⁰C
Ambient Temp Range -20⁰C to 50⁰C
Hazardous Area VPC is Group II Zone 1G IIB T4
SYSTEM AND SUPPLY
Supply voltage 115 / 230V ac, 50 – 60Hz (Switchable)
Zener Barrier/Computer Module 115 / 230V ac, 50 – 60Hz (Switchable)
Motor 380-440V ac, 50-60Hz, 3 phase, 250W
Supply voltage Consumption < 50 VA Single Phase
Approvals
    • MEPC 108 (49) – DNV, USCG, CCS and NKK.
    • MEPC 240(65) – DNV, CCS and NKK